top of page
Starflow_edited.jpg

THE DIVER

Dual Depth, Velocity, Barometer, and Optional Conductivity All In One Little Package

PHYSICAL SPECIFICATIONS

Material: Epoxy-sealed body, Marine Grade 316 Stainless Steel Mounting Bracket
Size: 5.3 x 2.1 x 0.8" (LxWxH)
Weight: 2.2 lbs with 30' of Cable
Operating temperature: 32°F to 140°F water temperature


VELOCITY AND DEPTH SPECIFICATIONS

Velocity Range:
– 0.065 ft/s to 2.6 ft/s
– 0.065 ft/s to 5.25 ft/s in one direction (default)
– 0.065 ft/s to 10.4 ft/s
– 0.065 ft/s to 43 ft/s
– Bidirectional velocity capability, set using configuration tools
Velocity Accuracy: Â±1% typical

Depth Range Ultrasonic Sensor:
0.78" up to 16.4' above top surface of the instrument
1.5" up to 16.4' from the base of the instrument
Depth Accuracy Ultrasonic Sensor :Typical ± 1%

Depth Range Absolute Pressure Sensor: 0 to 32'
Depth Accuracy Absolute Pressure Sensor:
Typical ± 0.19% for 0 to 16' range
Typical ± 0.38% for 0m to 32' range

​

Temperature: 32°F to 140°F
Temperature Resolution: 32°F

Flow Computation: Flow rate, totalized flow with companion logging devise
Channel type: Pipe, open channel, natural stream

Conductivity (optional): 0-200,000uS/cm Typically ±1% of measurement, returned either as
16-bit value (0 65535uS/cm) or 32-bit value (0-262,143uS/cm)
Compensation Conductivity (optional): 77°F default / set using configuration tools

Cable: 50ft, 6 way
Cable Options: User specified up to 160'


ELECTRICAL SPECIFICATIONS

Power Source Typical: External Battery 12V – 24V DC
Power Usage: 10V to 24V DC, 50µA standby, 100mA active for 1 sec
SDI-12: SDI-12V 1.3 recorder (1200 baud smart instrument channel)
RS 485: Modbus RTU


BAROMETER SPECIFICATIONS

Size: 3 x 1.7 x 0.78" (LxWxH)
Pressure Range: 0 to 100kPa
Accuracy: 0.25% FS

bottom of page